The Sun StorEdge[tm] S1 array is an ideal solution for rack-intensive environments where fast data transfers, efficient space utilization, and compatibility with a wide range of Sun[tm] servers are critical concerns. The device delivers excellent performance - up to 160MB/sec. throughput - while its 1U form factor, compact footprint, and a variety of rack options allow it to fit neatly into standard rack environments. Rack-optimization features such as front-to-back airflow, front-accessible hot-swap disks, front and rear LEDs, and 12-meter cabling help enable better utilization of precious rack space and help make servicing easier. The Sun StorEdge S1 array works with a variety of Sun Netra[tm] and general-purpose workgroup and enterprise servers. And together with Sun's other rack-optimized 1U servers and PCI system expander, the Sun StorEdge S1 array supports modular computing, helping companies to balance performance, storage capacity, and PCI connectivity - affordably.
Highlights
- Key
Applications:
Ideal incremental storage solution for all three tiers of an Internet architecture.
- Key Specifications:
System takes in air from the front and exhausts to the back, for quicker, more efficient cooling. Increased manageability with Lights-Out Management and Storage Subsystem Manager software, which allows remote monitoring of enclosure, drives, and temperature.
- Key Benefits:
1U form factor and variety of rack-mounting options enable system to fit 19-inch, 23-inch, 24-inch, and 600-mm racks. Three front-accessible hot-swap drive bays supporting 18.2GB and 36.4GB 10,000 rpm hard disk drives. Compatible with a variety of Sun servers including Sun Netra[tm]; backward compatible with the Netra st D130 array.
- Key Industries:
AC and DC power options and ruggedized, NEBS Level-3 packaging are ideal for deployment in a variety of powering environments and under less than ideal environmental conditions.
Sun StorEdge S1 Disk Array Specifications
|
|
| ARCHITECTURE |
| Carrier Features | Supports 19-in. and 24-in. rack configurations, with fixed-rail options Flame-resistant, fireproof metal enclosure NEBS Level-3 Certified |
| Status and sensors | Device and drive status information accessible from host server Front and rear LEDs for system and drive status |
| SCSI | Ultra3 SCSI LVD (100 MB/s) Maximum cable length 12 meters for LVD and 3 meters for SE SCSI |
| DISK DRIVES |
| Form factor |
3.5-inch low-profile, LVD |
| Supported drives |
18.2 GB or 36.4 GB, 10,000 rpm |
| Array Capacity |
Up to 3 hot-swap hard disk drives |
| SOFTWARE |
| Operating System |
Sun Solaris[tm] 2.6 Operating Environment and higher
Sun[tm] Cluster 3.0 (with Netra T1 AC200/DC200, Netra E1 PCI System Extender, and Sun StorEdge S1 array)
Remote monitoring through the included Sun StorEdge S1 Storage Subsystem Manager (SSM) 2.0 |
| SUPPORTED PLATFORMS |
| Servers |
Netra T1 AC200/DC200 Netra t 1120/1125 Netra t 1400/1405 Netra ct 400/800
Sun Enterprise[tm] 220R/420R Sun Fire 280R Sun Fire 15K |
| ENVIRONMENT |
| Power |
AC or DC |
| AC Power |
100-240 V AC, single-phase (47-63 Hz) |
| DC Power |
-48/-60 V DC |
| Input current |
Less than 2 A at 100V AC (150 W) Less than 4 A at -40V AC (150 W) |
| Operating temperature |
5º C to 40º C (41º F to 104º F), 5% to 85% relative humidity, noncondensing (not to exceed 0.024 kg water/kg of dry air) |
| Short-term operating temperature |
-5º C to 55º C (23º F to 131º F), 5% to 90% relative humidity, noncondensing (not to exceed 0.024 kg water/kg of dry air) |
| Nonoperating temperature |
-40º C to 70º C (-40º F to 158º F), 90% maximum relative humidity, noncondensing |
| Acoustic noise |
Less than 60dBa (GR-63-CORE Test Method) |
| Seismic |
Meets GR-63-CORE requirements for earthquake risk zone 4 |
| Heat output |
150 W, 512 BTUs/hr |
| REGULATIONS |
| Meets or exceeds the following requirements: |
| Safety | UL/CSA-60950, EN60950, IEC950 CB Scheme with all country deviations |
| RFI/EMI | EN55022/CISPR22 Class B, FCC CFR47 Part 15 Class B, EN61000-3-2, EN61000-3-3, EN 300 386 V1.2.1 (2000-03) - Telecom Center Only |
| Immunity | EN55024, EN 300 386 V1.2.1 (2000-03) - Telecom Center Only |
| Telcordia NEBS | GR-63-CORE, GR-1089-CORE, SR-3580 Level-3 |
| Regulatory Markings | CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, EK, UL/cUL, TUV-GS |
| Telcordia | NEBS Level-3 |
| KEY APPLICATIONS |
| Tier 1 | Web caching Video streaming Domain name device
Incremental storage for horizontal scaling Firewall Web hosting Authentication |
| Tier 2 | Boot device
Incremental storage for application servers Mail/messaging Network management Softswitch Billing |
| Tier 3 | Redundant boot device |
| DIMENSIONS AND WEIGHT |
| Height | 44 mm (1.73 in.) |
| Width | 436 mm (17.16 in.) |
| Depth | 450 mm (17.71 in.) |
| Weight (with drives) | 8.8 kg (19.4 lb.) |
|
|