As part of our broad family of Sun StorEdge[tm] Complete Storage Solutions, the Sun StorEdge[tm] D2 array perfectly complements Sun's scalable Volume and Workgroup servers. Additional cost-efficient server-based software RAID functionality provides the array with enhanced data availability. From departmental file sharing to transaction-intensive database environments, the Sun StorEdge D2 array can help you realize a low total cost of ownership. Meeting your demands for a simple, easy-to-manage, and quickly deployable workgroup storage array and optimized on the Solaris[tm] Operating Environment, the flexible Sun StorEdge D2 array, provides an optimal balance of performance and value. Sun Storage Automated Diagnostic Environment is an integral availability tool that provides health management services to help ensure high availability for Sun StorEdge arrays.
Sun StorEdge Complete Storage Solutions — providing you with comprehensive hardware, software, and services to solve your business challenges enterprise-wide.
Highlights
- Key
Applications:
Value priced, high data availability disk array providing lower total cost of ownership. Deployed on the robust Solaris[tm] Operating Environment and compatible with Sun's scalable lines of Sun Fire[tm] 280R and V880 servers, and the Sun Enterprise[tm] 220R, 250, 420R, 450 servers.
- Key Specifications:
Ultra3 SCSI bandwidth of up to 160 MB/sec delivers fast data access and data transfers for maximum performance. Flexible configurations enable the array to be customized for high-availability mirroring, or high performance to match demanding workgroup environments.
- Key Benefits:
Predicted steady-state uptimes in excess of 99.99 percent per array with RAID levels 5, 1, and 0+1 for continuous data protection. Application availability is enhanced by redundancy throughout the system coupled with the Sun Network Storage Agent utility for proactive fault detection and reporting on key components.
- Key Related Software:
- Sun StorEdge[tm] Availability Suite software
- Solstice DiskSuite[tm] software
- VERITAS Volume Manager
- VERITAS File System
Sun StorEdge D2 Array Specifications
|
|
| Host System Interface |
| Ultra3 SCSI Dual-port |
PCI card |
| Ultra SCSI 3, Low Voltage Differential Interface |
| Standard |
NCITS 336:2000 |
| Maximum SCSI bus length |
12 m |
| Disk Drives |
| Form factor |
3.5 in., low profile Ultra3 SCSI |
| Interface |
Ultra3 SCSI |
| Supported drives |
18.2 GB, 10,000 rpm
36.4 GB, 10,000 rpm |
| Configurations |
| Workgroup |
Up to 12 (1.0 in.) hot-swap drives, Ultra3 SCSI
Single or Dual Bus option
Two hot-swap, high-reliability power supplies
Redundant, hot-swappable fans |
| Hardware Platforms |
| Supported Platforms |
Sun Fire[tm] 280R, V480, and V880 servers
Sun Enterprise[tm] 220R, 250, 420R, and 450 servers
Sun Blade[tm] 100, 150, 1000 and 2000 workstations
Ultra[tm] 60 and 80 workstations
Netra[tm] 20 servers
Netra t 1400/1405 servers
|
| Software |
| Software Support |
Solaris[tm] 8 Operating Environment
Sun StorEdge[tm] Availability Suite software
Solstice DiskSuite[tm] software
Sun Network Storage Agent
VERITAS Volume Manger
VERITAS File System |
| Reliability, Availability, Serviceability |
| Redundancy |
Power supplies
Redundant, hot-swappable fans |
| High availability |
Software RAID 0, 1, 1+0, 3, 5
Ultra3 SCSI disk drives
Sun Network Storage Agent |
| Electrical |
| Input Voltage |
100-240 VAC, single phase |
| Power Requirements |
90-264 VAC (Single Phase 46-63 Hz) |
| Input Current |
5 A at 100 VAC or 2.5 A at 200 VAC |
| Power Consumption |
Idle 197W; Max. 246W |
| Environment |
| Operating |
5ºC to 40ºC (41ºF to 104ºF), 20% to 80% relative humidity, noncondensing |
| Nonoperating |
-20ºC to 60ºC (-4ºF to 140ºF), 93% relative humidity, noncondensing |
| Altitude |
-30 m to 3,048 m (-100 ft. to 10,000 ft.) |
| Vibration |
1.0 G, 5-500 Hz swept sine |
| Shock |
15 Gs, 11-ms, half sine |
| Operating Acoustic Noise |
6.6 bels (at 25ºC) (63.7dB measured sound power) |
| Idling Acoustic Noise |
6.4 bels (at 25ºC) (61.0dB measured sound power)
|
| Heat Output |
1,092 BTUs/hr. |
| Regulations |
| Meets or exceeds the following requirements: |
| Safety |
UL 1950, CSA C22.2-No. 950, TUV EN 60950 |
| Emission |
FCC Part 15 B Class B, CISPR 22 Class B, VCCI Class 2 |
| Immunity |
EMC Directive (89/336/EEC), EN50082-1 |
| Harmonics |
EMC Directive (89/336/EEC), EN60555-2 |
| Dimensions and Weights |
| Height |
17.7 cm (7.0 in.) |
| Width |
44.7 cm (17.6 in.) |
| Depth |
53.3 cm (21.0 in.) |
| Weight (without drives) |
19.3 kg (42.5 lb.) |
| Weight (with drives) |
28.4 kg (62.5 lb.) |
| Power Cord |
2 m (6.5 ft.) |
|
|
| Sun StorEdge D2 Bill of Materials |
Array Controller
|
540-5016
|
ESM (Environment Services Module) with Canister - Low Voltage Differential SCSI Controller Assembly |
Array Controller
|
340-7032
|
ESM Filler Panel, for single bus configuration |
Backplane/Centerplane
|
540-5158
|
12-Drive Chassis Assembly with Power Supply |
Backplane/Centerplane
|
375-3049
|
12-Slot SCSI Disk Backplane |
Backplane/Centerplane
|
370-4617
|
Empty 12-Drive Chassis/Midplane FRU |
Backplane/Centerplane
|
540-4943
|
Empty Chassis Assembly |
Cables
|
X311L
|
|
Cables
|
X312L
|
|
Cables
|
X314L
|
|
Cables
|
X317L
|
|
Cables
|
X383L
|
|
Cables
|
X384L
|
|
Cables
|
X386L
|
|
Cables
|
X3832A
|
External SCSI Cable, HD68 to VHDCI, 2M |
Cables
|
180-1998
|
IEC 320 C13 to AS 3112 - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1995
|
IEC 320 C13 to Asfnit 107 - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1997
|
IEC 320 C13 to BS 1363 - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1993
|
IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1996
|
IEC 320 C13 to CEI 23-16/VII - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1097
|
IEC 320 C13 to NEMA 5-15P - 15A/125V 2.5M Black, RoHS:Y |
Cables
|
180-1994
|
IEC 320 C13 to SEV 1011 - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
530-1819
|
Localized Power Cord Kit - Danish |
Cables
|
530-2453
|
Sun - 3rd Party HD68 Male to Female 6ft ($100 minimum) |
Cables
|
X1136A
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 0.8M |
Cables
|
530-2982
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 0.8M |
Cables
|
530-2983
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 1.2M |
Cables
|
X1137A
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 1.2M |
Cables
|
X3831B
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 10M |
Cables
|
530-2985
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 10M |
Cables
|
X1138A
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 2M |
Cables
|
530-2538
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 2M |
Cables
|
X3830B
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 4M |
Cables
|
530-2984
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 4M |
Disks
|
540-4910
|
18.2GB - 10000 RPM, Disk Assembly with 1" bracket (SPUD) |
Disks
|
X5248A
|
18.2GB - 10000 RPM, Disk Assembly with 1" bracket (SPUD) |
Disks
|
X5250A
|
36.4GB - 10000 RPM, Disk Assembly with 1 bracket |
Disks
|
540-4904
|
36.4GB - 10000 RPM, Disk Assembly with 1 bracket |
Disks
|
X5263A
|
73.4GB - 10000 RPM, Disk Assembly with 1 bracket |
Disks
|
540-5455
|
73.4GB - 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates and 1 of the following disks: |
Disks
|
540-6600
|
73.4GB - 10000 RPM, Disk Assembly with 1 bracket, 1 plate and 1 of the following disks, RoHS:Y |
Disks
|
390-0066
|
Fujitsu MAN3184MC |
Disks
|
390-0065
|
Fujitsu MAN3367MC |
Disks
|
390-0110
|
Fujitsu MAP3367NC |
Disks
|
390-0156
|
Fujitsu MAP3367NC |
Disks
|
390-0157
|
Fujitsu MAP3735NC |
Disks
|
390-0175
|
Fujitsu MAT3073NC |
Disks
|
390-0252
|
Fujitsu MAW3073NC (73.4GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0111
|
Hitachi DK32EJ-36NC |
Disks
|
390-0108
|
Hitachi DK32EJ-72NC |
Disks
|
390-0265
|
Hitachi HUS103073A (73.4GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0176
|
Hitachi HUS103073FL3800 |
Disks
|
340-5928
|
Plate |
Disks
|
340-7269
|
Plate, RoHS:Y |
Disks
|
341-1986
|
Plate, RoHS:Y |
Disks
|
390-0085
|
Seagate ST318305LC |
Disks
|
390-0069
|
Seagate ST336605LC |
Disks
|
390-0109
|
Seagate ST336607LC |
Disks
|
390-0174
|
Seagate ST373207LC |
Disks
|
390-0275
|
Seagate ST373207LC (73.4GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0106
|
Seagate ST373307LC |
Fan
|
540-3323
|
Fan Canister |
Power
|
300-1507
|
360W Power Supply |
Rack
|
595-4999
|
72 inch StorEdge Expansion Cabinet Front Door Kit |
Rack
|
X9818A
|
72 inch StorEdge Expansion Cabinet Front Door Kit |
Rack
|
SG-XARY030A
|
72 inch Sun StorEdge Expansion Cabinet |
Rack
|
595-4706
|
72 inch Sun StorEdge Expansion Cabinet |
Rack
|
X9606A
|
Tower Stand Kit |
SCSI
|
SG-XPCIE2SCSIU320Z
|
Dual-Channel Ultra320 LVD SCSI PCI Express Adapter, RoHS:Y |
SCSI
|
375-3357
|
Dual-Channel Ultra320 LVD SCSI PCI Express Adapter, RoHS:Y |
SCSI
|
375-3057
|
PCI Dual Ultra3 SCSI Host Adapter (LVD) |
SCSI
|
X6758A
|
PCI Dual Ultra3 SCSI Host Adapter (LVD) |
SCSI
|
SGXPCI1SCSILM320-Z
|
PCI Single Ultra320 SCSI Adapter |
SCSI
|
375-3366
|
PCI Single Ultra320 SCSI Adapter |
SCSI
|
375-3191
|
PCI/PCI-X Dual Ultra320 SCSI Adapter |
SCSI
|
SG-XPCI2SCSI-LM320
|
PCI/PCI-X Dual Ultra320 SCSI Adapter |
|
|
|