On Queue
Product Range |
|
|
|
|
|
 |
 |
 |
 |
Sun StorEdge 3310 SCSI Array |
(877) 667-8383 |
|
Demanding workgroup environments call for an easy-to-use, simple-to-manage, highly flexible storage array platform. The versatile Sun StorEdge[tm] 3310 SCSI Array is a low-profile, high-density, modular storage system designed for fast-growing environments. Packed with enterprise features, such as remote management service, this cost-effective array meets the growing needs of workgroups and departments wherever they may be located within your organization. The space-efficient 12-drive array supports hundreds of gigabytes of storage, one or two RAID controllers, 128 LUNs, and multiple host connections. The highly adaptable design makes it easy to add capacity in single-drive increments or with low-cost expansion units. The system's single or dual RAID controllers and simple Web interface helps enable customers to quickly and cost-effectively expand capacity, adding hundreds of drives and thousands of LUNs. Designed to withstand some of the harshest environments, the array is ruggedized to meet full NEBS Level 3 certification, and the air, land, and marine deployment of the MIL-STD-810F specification.
Highlights
- Key
Applications:
- Fast-growing I/O intensive networks
- Desktop and work applications requiring value-based external RAID storage
- Small databases
- File sharing
- E-mail
- Web caching
- Web sharing
- Key Specifications:
- Compact, high-density 2U rack unit provides high performance/high availability/high functionality SCSI RAID storage
- Low-cost RAID controller with high-availability configuration options
- Supports expansion trays; up to 36 disks per controller
- Ruggedized for NEBS Level 3 certification and MIL-STD-810F compliant for air, land, and marine deployment
- Highly scalable array can grow from two drives to hundreds in one-drive increments
- Up to 36 drives per one or pair of RAID controllers
- Up to 3.4TB per Sun StorEdge Expansion Rack
- Key Benefits:
- Flexible configuration
- Remote management
- Cost-effective
- Small form factor
- Reduced management costs
- Easy to use, simple to manage
- Key Related Hardware:
- Sun Enterprise[tm] 220R, 420R, 250, and 450 servers
- Sun Fire[tm] V120, 280R, V480, and V880 servers
- Netra[tm] 120, 20, t 1400/1405 servers
- Sun Blade[tm] 1000 and 2000 workstations
- Sun LX50 server
- Key Industries:
- Industrial
- Retail
- Life Sciences
- Telecommunications
- Government
Sun StorEdge 3310 SCSI Array Specifications
|
|
| Host System Interface |
| Number of ports |
Up to two server nodes (user configurable) |
| Interface type |
Ultra[tm] 160 SCSI Low Voltage Differential (LVD) |
| Maximum cable length |
10 m |
| Maximum point-to-point length |
12 m |
| Software |
| Configuration and management |
Sun StorEdge Configuration Service software (included) |
| Monitoring and event notification |
Sun StorEdge Diagnostic Reporter software (included) |
| Operating environments |
Solaris[tm] Operating Environment 8 and 9
Sun Linux 5.0, on LX50 platform
Microsoft Windows NT 4.0 / Windows 2000 server
Red Hat Linux distribution v7.3
|
| Supported software |
Sun Cluster 3.0 software
Sun Solstice DiskSuite[tm] software
VERITAS Volume Manager software
|
| Hardware Platforms |
| Hardware compatibility |
Sun Enterprise[tm] 220R, 420R, 250, and 450 servers
Sun Fire[tm] V120, 280R, V480, and V880 servers
Netra[tm] 120, 20, t 1400/1405 servers
Sun Blade[tm] 1000 and 2000 workstations
Sun LX50 server
|
| Disk Drives |
| Capacity |
2 to 36 drives (1 hardware RAID, up to 2 additional expansion units) |
| Form factor |
3.5-in., low-profile Ultra 160 SCSI |
| Interface |
Ultra 160 SCSI |
| Supported drives |
36 GB, 10,000 RPM |
| Configurations |
| Array unit |
5 to 12 disk drives
Single or dual SCSI bus options (user configurable)
Single, dual, or paired (redundant) hardware RAID controllers
512 MB of battery-protected cache per controller (fixed)
|
| Expansion unit |
5 to 12 disk drives
Single or dual SCSI bus options (user configurable) |
| Reliability, Availability, Serviceability (RAS) |
| Reliability |
Telco and military certified rugged
Load-sharing/load-balancing power supplies |
| Availability |
Dual redundant RAID controllers
Dual redundant power supplies
Electrically isolated redundant cooling fans
Redundant event-management modules
Support for RAID levels 0, 1, 0+1, 3, 5, 3+0, 5+0
RAID controller cache is backed by 72-hr hold-time during power loss
|
| Serviceability |
Nondisruptive firmware upgrades, via SSCS
Hot-swap RAID controllers when in dual redundant RAID controller configuration
Hot-swap disk drives
Hot-swap power supplies
Hot-swap cooling fans
Hot-swap event-management modules
|
| Electrical |
| AC Input |
| Voltage |
110 to 240 VAC, single phase |
| Power requirement |
90 to 132 VAC or 180 to 264 VAC (47-63 Hz) |
| Current per input |
100 to 240 VAC, 50-60 Hz, 5.0-1.7 A |
| DC Input |
| Voltage |
-48 or -60 VDC, 18A |
| Power requirement |
-36 to -75 VDC |
| Current per input |
-48 or -60 VDC, 18A |
| Environmental |
| Operating |
| Temperature |
5°C to 40°C (41°F to 104°F) |
| Humidity |
10% to 90% relative to 38°C, noncondensing |
| Altitude |
-30 m to 3048 m (-100 to 10,000 ft) |
| Shock |
5.0 G, 11-ms, half-sine |
| Vibration |
0.2 G, 5-500 Hz, swept-sine |
| Nonoperating |
| Temperature |
-40°C to 65°C (-40°F to 149°F) |
| Humidity |
0% to 90% relative to 27°C, noncondensing |
| Altitude |
-30 m to 12,192 m (-100 to 40,000 ft) |
| Shock |
15.0 G, 11-ms, half-sine |
| Vibration |
1.0 G, 5-500 Hz, swept-sine |
| Regulations |
| Meets or exceeds the following requirements: |
| Safety |
UL Listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark; GS Mark |
| Emission |
FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003, VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S-Mark
|
| Harmonics |
IEC 61000-3-2:2000, IEC 61000-3-3:1995/A1:2001
|
| Immunity |
CSIPR 24 EN 55024
|
| Other |
NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386
|
| Dimensions and Weight |
| Height |
8.8 cm (3.5 in.) (2.0u) |
| Width |
44.7 cm (17.6 in.) |
| Depth |
53.3 cm (21.0 in.) |
| Weight |
22.7 kg (50.0 lb maximum) |
|
|
| Sun StorEdge 3310 Bill of Materials |
Array Controller
|
370-5403
|
512MB RAID Controller Module |
Array Controller
|
XTA-3310-CTRL-512M
|
512MB RAID Controller Module |
Array Controller
|
370-5533
|
Battery |
Array Controller
|
370-5394
|
Event Monitoring Unit (EMU) |
Array Controller
|
370-5396
|
Ultra-160 JBOD I/O Module, 2U Expansion Unit |
Array Controller
|
370-5397
|
Ultra-160 RAID I/O Module, 2U RAID Unit |
Backplane/Centerplane
|
370-5393
|
JBOD, LVD Chassis & Midplane |
Backplane/Centerplane
|
370-5524
|
RAID Chassis & Midplane Assembly |
Cables
|
X311L
|
|
Cables
|
X312L
|
|
Cables
|
X314L
|
|
Cables
|
X317L
|
|
Cables
|
X383L
|
|
Cables
|
X384L
|
|
Cables
|
X386L
|
|
Cables
|
370-6627
|
DB-9M to DB-9F Serial Cable, 1.8M |
Cables
|
370-6630
|
DC Input Power Cable |
Cables
|
370-6629
|
Ethernet Cable, 35-88730002 |
Cables
|
X3831A
|
External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 10M |
Cables
|
X3830A
|
External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 4M |
Cables
|
530-2454
|
External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 4M |
Cables
|
530-2452
|
External SCSI Cable, HD68 to VHDCI, 0.8M |
Cables
|
X1132A
|
External SCSI Cable, HD68 to VHDCI, 0.8M |
Cables
|
X3832A
|
External SCSI Cable, HD68 to VHDCI, 2M |
Cables
|
180-1998
|
IEC 320 C13 to AS 3112 - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1995
|
IEC 320 C13 to Asfnit 107 - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1997
|
IEC 320 C13 to BS 1363 - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1993
|
IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1996
|
IEC 320 C13 to CEI 23-16/VII - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
180-1097
|
IEC 320 C13 to NEMA 5-15P - 15A/125V 2.5M Black, RoHS:Y |
Cables
|
180-1994
|
IEC 320 C13 to SEV 1011 - 10A/250V 2.5M Black, RoHS:Y |
Cables
|
530-1819
|
Localized Power Cord Kit - Danish |
Cables
|
370-5528
|
RAID to JBOD Expansion cable, 0.45M, 35-00000131-02 |
Cables
|
370-5405
|
Single Bus SCSI Jumper cable, 0.3M, 35-00000131-01 |
Cables
|
530-2453
|
Sun - 3rd Party HD68 Male to Female 6ft ($100 minimum) |
Cables
|
530-2455
|
Sun - 3rd Party HD68 Male to VHDCI 40ft ($100 minimum) |
Cables
|
530-3323
|
Ultra-3 SCSI Cable, HD68/VHDCI, 1.2M |
Cables
|
X1135A
|
Ultra-3 SCSI Cable, HD68/VHDCI, 1.2M |
Cables
|
X1136A
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 0.8M |
Cables
|
530-2982
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 0.8M |
Cables
|
530-2983
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 1.2M |
Cables
|
X1137A
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 1.2M |
Cables
|
X3831B
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 10M |
Cables
|
530-2985
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 10M |
Cables
|
530-2538
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 2M |
Cables
|
X1138A
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 2M |
Cables
|
X3830B
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 4M |
Cables
|
530-2984
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 4M |
Cables
|
370-4917
|
VHDCI-68 LVD SCSI Terminator |
Cables
|
XTA-3310-SC-TERM
|
VHDCI-68 LVD SCSI Terminator |
Cables
|
XTA-3320-SC-TERM
|
VHDCI-68 LVD SCSI Terminator Board, RoHS:YL |
Cables
|
371-0826
|
VHDCI-68 LVD SCSI Terminator Board, RoHS:YL |
Disks
|
540-5562
|
|
Disks
|
540-5735
|
146.8GB - 10000 RPM, Disk Assembly |
Disks
|
540-6058
|
146.8GB - 10000 RPM, Disk Assembly |
Disks
|
540-6450
|
146.8GB - 10000 RPM, Disk Assembly |
Disks
|
XTA-3310-146GB-10K
|
146.8GB - 10000 RPM, Disk Assembly |
Disks
|
XTA-SC1NC-146G10K
|
146.8GB - 10000 RPM, Disk Assembly |
Disks
|
XTA-SC1NC-146G15K
|
146.8GB - 15000 RPM, Disk AssemblyL |
Disks
|
540-6494
|
146.8GB - 15000 RPM, Disk AssemblyL |
Disks
|
540-6132
|
300.0GB - 10000 RPM, Disk Assembly |
Disks
|
XTA-SC1NC-300G10K
|
300.0GB - 10000 RPM, Disk Assembly |
Disks
|
540-6366
|
300GB - 10000 RPM, Disk Assembly |
Disks
|
540-5522
|
36.4GB - 10000 RPM, Disk Assembly |
Disks
|
XTA-3310-36GB-10K
|
36.4GB - 10000 RPM, Disk Assembly |
Disks
|
XTA-3310-36GB-15K
|
36.4GB - 15000 RPM, Disk Assembly |
Disks
|
540-6121
|
36.4GB - 15000 RPM, Disk Assembly |
Disks
|
540-6448
|
73.4GB - 10000 RPM, Disk Assembly |
Disks
|
540-6056
|
73.4GB - 10000 RPM, Disk Assembly |
Disks
|
540-5563
|
73.4GB - 10000 RPM, Disk Assembly |
Disks
|
XTA-3310-73GB-10K
|
73.4GB - 10000 RPM, Disk Assembly |
Disks
|
XTA-SC1NC-73G10K
|
73.4GB - 10000 RPM, Disk Assembly |
Disks
|
XTA-3310-73GB-15K
|
73.4GB - 15000 RPM, Disk Assembly |
Disks
|
540-6057
|
73.4GB - 15000 RPM, Disk Assembly |
Disks
|
540-6097
|
73.4GB - 15000 RPM, Disk Assembly |
Disks
|
540-6449
|
73.4GB - 15000 RPM, Disk AssemblyL |
Disks
|
XTA-SC1NC-73G15K
|
73.4GB - 15000 RPM, Disk AssemblyL |
Disks
|
390-0154
|
Fujitsu MAP3147NC |
Disks
|
390-0156
|
Fujitsu MAP3367NC |
Disks
|
390-0157
|
Fujitsu MAP3735NC |
Disks
|
390-0132
|
Fujitsu MAS3367NC |
Disks
|
390-0153
|
Fujitsu MAS3735NC |
Disks
|
390-0175
|
Fujitsu MAT3073NC |
Disks
|
390-0178
|
Fujitsu MAT3147NC |
Disks
|
390-0185
|
Fujitsu MAT3300NC |
Disks
|
390-0200
|
Fujitsu MAU3036NC |
Disks
|
390-0203
|
Fujitsu MAU3073NC |
Disks
|
390-0252
|
Fujitsu MAW3073NC (73.4GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0253
|
Fujitsu MAW3147NC (146.8GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0254
|
Fujitsu MAW3300NC |
Disks
|
390-0259
|
Fujitsu MAX3036NC |
Disks
|
390-0260
|
Fujitsu MAX3073NC (73.4GB - 15000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0261
|
Fujitsu MAX3147NC (146.8GB - 15000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0155
|
Hitachi DK32EJ-14NC |
Disks
|
390-0111
|
Hitachi DK32EJ-36NC |
Disks
|
390-0108
|
Hitachi DK32EJ-72NC |
Disks
|
390-0179
|
Hitachi HUS103014FL3800 (146.8GB - 10000 RPM Ultra-320) |
Disks
|
390-0266
|
Hitachi HUS103014FL3800 (146.8GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0265
|
Hitachi HUS103073A (73.4GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0176
|
Hitachi HUS103073FL3800 |
Disks
|
390-0207
|
Hitachi HUS151414VL3800 (146GB - 15000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0201
|
Hitachi HUS151436VL3800 |
Disks
|
390-0204
|
Hitachi HUS151473VL3800 (73.4GB - 15000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0361
|
Hitachi HUS153014VL3800 (146.8GB - 15000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0360
|
Hitachi HUS153073VL3800 (73.4GB - 15000 RPM Ultra-320), RoHS:YL |
Disks
|
390-0177
|
Seagate ST3146707LC |
Disks
|
390-0276
|
Seagate ST3146707LC (146.8GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0145
|
Seagate ST3146807LC |
Disks
|
390-0205
|
Seagate ST3146854LC (146.8GB - 15000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0327
|
Seagate ST3146855LC (146.8GB - 15000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0184
|
Seagate ST3300007LC |
Disks
|
390-0277
|
Seagate ST3300007LC (300.0GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0069
|
Seagate ST336605LC |
Disks
|
390-0109
|
Seagate ST336607LC |
Disks
|
390-0131
|
Seagate ST336753LC |
Disks
|
390-0199
|
Seagate ST336754LC |
Disks
|
390-0174
|
Seagate ST373207LC |
Disks
|
390-0275
|
Seagate ST373207LC (73.4GB - 10000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0106
|
Seagate ST373307LC |
Disks
|
390-0143
|
Seagate ST373453LC |
Disks
|
390-0202
|
Seagate ST373454LC (73.4GB - 15000 RPM Ultra-320), RoHS:Y |
Disks
|
390-0325
|
Seagate ST373455LC (73.4GB - 15000 RPM Ultra-320), RoHS:Y |
Power
|
371-0108
|
420 Watt AC Input Power Supply, RoHS:YL |
Power
|
370-5398
|
420 Watt AC Power Supply / Fan Module |
Power
|
371-0109
|
420 Watt DC Input Power Supply, RoHS:YL |
Power
|
370-6776
|
AC Power Supply / Fan Module, 2U |
Power
|
XTA-3000-2UAC-KIT
|
AC Power Supply / Fan Module, 2U |
Power
|
XTA-3310-DC-KIT
|
DC Power Supply / Fan Module |
Power
|
370-5527
|
DC Power Supply / Fan Module |
Power
|
370-6798
|
DC Power Supply / Fan Module, 2U |
Power
|
XTA-3000-2UDC-KIT
|
DC Power Supply / Fan Module, 2U |
Rack
|
370-5643
|
Rackmount Kit, 2U, 19" Wide, 22"-28" Deep (use with Sun Rack 900) |
Rack
|
XTA-3310-RK-19S
|
Rackmount Kit, 2U, 19" Wide, 22"-28" Deep (use with Sun Rack 900) |
Rack
|
XTA-3310-RK-19L
|
Rackmount Kit, 2U, 19" Wide, 28"-36" Deep (use with StorEdge 72" Expansion Cabinet) |
Rack
|
370-5648
|
Rackmount Kit, 2U, 19" Wide, 28"-36" Deep (use with StorEdge 72" Expansion Cabinet) |
Rack
|
370-6166
|
SE3000 2U Family Universal Rackmount Kit |
Rack
|
XTA-3000-2URK-19U
|
SE3000 2U Family Universal Rackmount Kit |
Rack
|
XTA-3000-2U-R2T
|
Sun StorEdge 3000 2U Rack Ready to Tabletop conversion kit |
Rack
|
370-7596
|
Sun StorEdge 3000 2U Rack Ready to Tabletop conversion kit |
Rack
|
370-6179
|
Sun StorEdge 3000 Family Tabletop Conversion Kit, includes outer skin with feet and screws |
Rack
|
XTA-3310-DESK-KIT
|
Sun StorEdge 3000 Family Tabletop Conversion Kit, includes outer skin with feet and screws |
Rack
|
XTA-3310-RK-19C
|
Telco Rackmount Kit, Center Mount, 2U, 19" Wide |
Rack
|
XTA-3000-2URK-19C
|
Telco Rackmount Kit, Center Mount, 2U, 19" Wide |
Rack
|
370-5649
|
Telco Rackmount Kit, Center Mount, 2U, 19" Wide |
Rack
|
370-5650
|
Telco Rackmount Kit, Flush/Front Mount, 2U, 19" Wide |
Rack
|
XTA-3000-2URK-19F
|
Telco Rackmount Kit, Flush/Front Mount, 2U, 19" Wide |
Rack
|
XTA-3310-RK-19F
|
Telco Rackmount Kit, Flush/Front Mount, 2U, 19" Wide |
SCSI
|
X2222A
|
Dual FastEthernet / Dual SCSI PCI Adapter |
SCSI
|
501-5727
|
Dual FastEthernet / Dual SCSI PCI Adapter |
SCSI
|
501-6635
|
Dual GigabitEthernet / Dual SCSI PCI Adapter |
SCSI
|
X4422A
|
Dual GigabitEthernet / Dual SCSI PCI Adapter |
SCSI
|
X9265A
|
Dual Ultra-320 SCSI/RAID |
SCSI
|
370-6682
|
Dual Ultra-320 SCSI/RAID |
SCSI
|
375-3357
|
Dual-Channel Ultra320 LVD SCSI PCI Express Adapter, RoHS:Y |
SCSI
|
SG-XPCIE2SCSIU320Z
|
Dual-Channel Ultra320 LVD SCSI PCI Express Adapter, RoHS:Y |
SCSI
|
X6758A
|
PCI Dual Ultra3 SCSI Host Adapter (LVD) |
SCSI
|
375-3057
|
PCI Dual Ultra3 SCSI Host Adapter (LVD) |
SCSI
|
375-3365
|
PCI Dual Ultra320 SCSI Adapter, RoHS:YL |
SCSI
|
SGXPCI2SCSILM320-Z
|
PCI Dual Ultra320 SCSI Adapter, RoHS:YL |
SCSI
|
SG-XPCI2SCSI-LM320
|
PCI/PCI-X Dual Ultra320 SCSI Adapter |
SCSI
|
375-3191
|
PCI/PCI-X Dual Ultra320 SCSI Adapter |
SCSI
|
X1018A
|
Single-Ended Fast/Wide SCSI/FastEthernet (SunSwift/S) |
SCSI
|
501-2739
|
Single-Ended Fast/Wide SCSI/FastEthernet (SunSwift/S) |
|
|
|