On Queue
Product Range |
|
|
|
|
|
 |
 |
 |
 |
Sun Storedge T3 Array for the Enterprise |
(877) 667-8383 |
|
For midrange to enterprise computing, the Sun StorEdge[tm] T3 array for the enterprise offers a flexible, scalable approach to growing storage while reducing total cost of ownership. Full redundancy helps ensure that no single failure inhibits data availability. Two high-performance RAID controllers provide dual fibre-channel interfaces, each accessing a separate array of nine disk drives. Should a controller fail, the alternate controller provides access to all 18 drives. In addition, each controller has its own cache, delivering up to 2 GB of memory for fast access to frequently accessed data. Recently written information is mirrored in cache on both controllers, providing extra prevention against data loss. The Sun StorEdge T3 array for the enterprise delivers outstanding three-way scalability of capacity, performance and availability. As capacity scales, additional cache provides consistent high performance, while additional data paths and redundancy increase availability. Additional capabilities can also be added through firmware download or controller upgrades for outstanding investment protection. Sun Storage Automated Diagnostic Environment is an integral availability tool that provides health management services to help ensure high availability for Sun StorEdge arrays.
Highlights
- Key
Applications:
- Meets the demands of a wide range of applications and workload requirements such as online transaction processing, decision support, messaging, web hosting, and high-performance computing environments
- Represents a new and advanced generation of flexible, reliable storage systems that allow businesses to scale storage capacity, performance, and availability seamlessly as business needs grow
- Sun StorEdge T3 with 256MB of cache features multi-platform support and is available in configurations containing dual Sun StorEdge FC switches
- Sun StorEdge T3 with 1 GB of cache features multi-platform support for the latest SAN features and supports the latest versions of Microsoft Windows, Red Hat Linux, IBM AIX, and HP/UX
- Sun StorEdge administration software offers management, configuration, and health monitoring using an Ethernet connection separated from data traffic
- Key Specifications:
- Path fail-over with mirrored cache with hot-swap/redundant RAID controllers, power supplies, cooling fans, backup batteries, interconnect cards, and drives
- Modular flexibility combined with full, front-to-back fibre architecture allows configuration for high transaction, high bandwidth, or high performance computing
- Sun StorEdge Component Manager software offers management, configuration, and health monitoring
- Linear scalability to a massive 169TB on a single server
- Host driver-based failover and load balancing through Sun StorEdge Traffic Manager minimizes application interruptions and delays
- Sun StorEdge Component Manager software allows easy and simple centralized single-point administration
- Two host connections help ensure data availability by providing alternative paths to the array's data
- Fabric connectivity to the host is enabled with the Sun StorEdge network FC switch
- Open system connectivity includes support for HP-UX, IBM-AIX, Linux, Windows NT, and Solaris hosts
- Key Benefits:
- Three-way scalability: As capacity is added, performance increases linearly and availability/reliability remain consistent
- Simplicity: Easy to use, manage, monitor, and control from a single, central administration console
- World-class Sun service and support
- Ability to upgrade cache from 512 MB to 2 GB provides investment protection
- An extensive qualification matrix helps ensure that most storage configurations can be supported
- All replaceable units are fully redundant and hot swappable, eliminating single point of failure
- Key Related Software:
- Sun StorEdge[tm] Availability Suite software
- Sun StorEdge Performance Suite software
- Sun StorEdge Resource Management Suite software
- Sun StorEdge Utilization Suite software
- Key Industries:
The Sun StorEdge T3 array helps maximize performance in online transaction, decision support, messaging, Web hosting, and high-performance computing environments within industries such as manufacturing, government, finance, and entertainment
Sun Storedge A5200 Disk Array Specifications
|
|
| STANDARD INTERFACES |
| Drives | FC-SCA-2 (3.5-in. drives) |
| Controller card | Native LC fibre channel connector RJ45 10/100 Base-T network connector RJ45 RS-232 connector |
| Loop cards | DB-9 connector |
| Power connector | CEE 22-V (latching, U.S. only) |
| Power cables | Two NEMA 5-15P |
| DRIVES |
Dual-ported bi-directional FC-AL Nine per enclosure / Two enclosures per unit |
| MAXIMUM SYSTEM RAW STORAGE CAPACITIES |
Max. System Capacities |
Max. Cabinet (72 drives) |
Max. System (32 cabinets) |
| 36.7 GB drive (10K/15K RPM) | 2.6 TB | 82.9 TB |
| 73.4 GB drive (10K RPM) | 5.2 TB | 169.1 TB |
| 181.6 GB drive (7.2K RPM) | 13.0 TB | 417.0 TB |
|
| HOST SYSTEM INTERFACE |
| Host System Interface |
Sun - 1 GB PCI (single and dual) and 1 GB cPCI (dual) fabric adapter (optical)
Sun - 2 GB PCI (single and dual) fabric
Sun - SBus FC-AL adapter (optical GBIC)
Microsoft - Emulex L8000F1-N1
HP - HP A5158A*
IBM - IBM FC#6227*
Linux - QLogic QLA2200F/66*
|
|
*All non-Sun host bus adapters supported by third-party vendor.
|
| HOST SOFTWARE |
| Operating System |
Sun Solaris[tm] 2.6, 7, 8, 9 Operating Environment per enclosure
Microsoft Windows NT 4.0 (SP6 and SP6A) Operating Environment
Microsoft Windows 2000 Advanced Server (SP2)
Red Hat Linux 7.2 Operating Environment
HP-UX 11.0 Operating Environment
IBM AIX 4.3.3, 5.11 Operating Environment
|
| Application Software |
VERITAS Volume Manager software (Tier 2 license included)
Sun StorEdge Component Manager software (included)
Sun StorEdge Management Console software (included)
Sun[tm] Cluster 3.0 update 2 software
|
| HARDWARE PLATFORMS |
| Platforms |
Sun Enterprise[tm] 10000 servers
Sun Enterprise 3x00 - 6x00 servers
Sun Fire[tm] 280R, 3800, 4800, 4810, 6800, V480, V880, 12K and 15K servers
Sun Enterprise 220R, 250, 420R, 450 servers
Ultra[tm] 60, 80 workstations
Netra[tm] t 1120/1125, 1400/1405, 20 servers
Intel Pentium III or higher (Microsoft Windows NT, Windows 2000, Linux)
HP 9000 N- or L-Class
IBM RS/6000
|
| FIELD REPLACEABLE UNITS |
| Drives |
Front |
| Power/cooling units |
Rear |
| Loop cards |
Rear |
| Controller card |
Rear |
| All FRUs are hot-swappable and have FRU IDs |
| CONTROLLER CARD |
| One RAID controller card/tray |
RAID levels 0, 1(1+0), 5
Up to 16 LUNs per unit
LUN masking/slicing
Network Time Protocol (NTP) support
Persistent Group Reservation (PGR) support
Configurable hot spare
Single host FC-AL interface
Two FC-AL drive loops
Dual speed network connection
RS-232 serial service port
256-MB or 1-GB data cache options
Hardware pipelined XOR
|
| PRECONFIGURED STORAGE |
| Preconfigured | RAID 5 |
| STORAGE NETWORK INTERCONNECT |
| Storage Network Interconnect |
Native LC fibre-channel connection
Max. multimode optical fiber length of 500 meters
|
| UNIT INTERCONNECT |
| Two redundant loop cards per enclosure |
FC-AL circuitry
Environmental/sense processor
|
| POWER AND COOLING |
| Power/cooling units |
Two per enclosure
Integrated backup battery power for cache destage
Auto-ranging power supplies
Dual line cords
Redundant fans
|
| POWER |
| Input power | 450 W maximum |
| Input current | 5A maximum |
| AC power | 100-240 VAC @ 47-63 Hz single phase |
| Heat output | 1540 BTU/hr, maximum |
| Operating | 5ºC to 35ºC (41ºF to 95ºF), with maximum gradient 20ºC per hour, 20% to 80% relative humidity, noncondensing, maximum gradient 10% per hour Altitude: -305 m (-1,000 ft.) to 3048 m (10,000 ft.) Shock: 4.0 g for maximum duration of 11 ms (half-sinewave) Vibration: 5 to 500 Hz @ 0.25 g sinusoidal |
| Nonoperating | -20ºC to 60ºC (-4ºF to 149ºF), with maximum gradient 20ºC per hour, 5% to 93% relative humidity, noncondensing, maximum gradient 10% per hour Altitude: -305 m (-1,000 ft.) to 12,192 m (40,000 ft.) Shock: 10.0 g for maximum duration of 11 ms (half-sinewave) Vibration: 5 to 500 Hz @ 1.0 g sinusoidal |
| ACOUSTIC NOISE |
| Sound power operating (sequential) | LWAd = 6.6 Bels* |
| Sound power idle | LWAd = 6.6 Bels* |
| Airflow clearance | 12 inches-back side |
*LWAd (1 Bel=10dB)
Declared noise emissions in accordance with ISO 9296, measured at 23ºC |
| REGULATIONS |
| Meets or exceeds the following requirements: |
| RFI/EMI | FCC Class A |
| Safety | UL/CSA CE Y2K compliant FC-AL standards |
| DIMENSIONS AND WEIGHT |
| Height | 27.94 cm (11 in.) (7U) |
| Width | 44.45 cm (17.5 in.) |
| Depth | 46.99 cm (18.5 in.) |
| Weight | 60.3 kg (134 lb. maximum, with half-height drives) |
|
|
| Sun StorEdge T3 Bill of Materials |
Array Controller
|
375-0084
|
T3 Array Controller FRU |
Array Controller
|
501-5710
|
T3+ Array Controller FRU |
Array Controller
|
X9647A
|
T3+ Array Controller FRU |
Backplane/Centerplane
|
540-4343
|
Chassis |
Backplane/Centerplane
|
375-0083
|
Midplane |
Backplane/Centerplane
|
370-3990
|
T3 Chassis with Midplane Assembly |
Cables
|
530-2842
|
DB-9 Interconnect Cable, 330 mm |
Cables
|
530-2843
|
DB-9 Interconnect Cable, 600 mm |
Cables
|
370-4119
|
Diagnostic Cable Kit |
Cables
|
X9715A
|
Fibre Optical Cable SC/SC, 5M |
Cables
|
370-3989
|
Media Interface Adapter, DB-9 to SC Duplex |
Cables
|
537-1006
|
Sun - 3rd Party SC to SC, 15m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum) |
Cables
|
X978A
|
Sun - 3rd Party SC to SC, 15m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum) |
Cables
|
X973A
|
Sun - 3rd Party SC to SC, 2m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum) |
Cables
|
537-1004
|
Sun - 3rd Party SC to SC, 2m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum) |
Cables
|
537-1020
|
Sun - 3rd Party SC to SC, 50m, Multimode, Duplex, 50/125um, Ceramic, Plenum ($100 minimum) |
Disks
|
540-4287
|
18.2GB - 10000 RPM FC-AL, Disk Assembly FRU with one bracket |
Disks
|
540-4440
|
18.2GB - 10000 RPM FC-AL, Disk Assembly with one bracket |
Disks
|
X6716A
|
18.2GB - 10000 RPM FC-AL, Disk Assembly with one bracket |
Disks
|
X6714A
|
36.4GB - 10000 RPM FC-AL, Disk Assembly with one bracket |
Disks
|
540-4367
|
36.4GB - 10000 RPM FC-AL, Disk Assembly with one bracket |
Disks
|
540-4519
|
73.4GB - 10000 RPM FC-AL, Disk Assembly with one bracket |
Disks
|
X6713A
|
73.4GB - 10000 RPM FC-AL, Disk Assembly with one bracket |
Disks
|
540-4303
|
Bracket |
Disks
|
390-0095
|
Fujitsu MAN3367FC (36.4GB - 10000 RPM FC-AL) |
Disks
|
390-0096
|
Fujitsu MAN3735FC (73.4GB - 10000 RPM FC-AL) |
Disks
|
390-0116
|
Fujitsu MAP3735FC (73.4GB - 10000 RPM FC-AL) |
Disks
|
390-0169
|
Fujitsu MAT3073FC (73.4GB - 10000 RPM FC-AL) |
Disks
|
390-0117
|
Hitachi DK32EJ-72FC (73.4GB - 10000 RPM FC-AL) |
Disks
|
390-0170
|
Hitachi HUS1073FA (73.4GB - 10000 RPM FC-AL) |
Disks
|
390-0054
|
IBM DDYF-T18350 (18.2GB 10000 RPM FC-AL) |
Disks
|
390-0057
|
IBM DDYF-T36950 (36.4GB - 10000 RPM FC-AL) |
Disks
|
390-0017
|
Seagate ST118202FC (18.2GB 10000 RPM FC-AL) |
Disks
|
390-0023
|
Seagate ST136403FC (36.4GB - 10000 RPM FC-AL) |
Disks
|
390-0036
|
Seagate ST173404FC (73.4GB - 10000 RPM FC-AL) |
Disks
|
390-0053
|
Seagate ST318304FC (18.2GB 10000 RPM FC-AL) |
Disks
|
390-0072
|
Seagate ST336605FC (36.4GB - 10000 RPM FC-AL) |
Disks
|
390-0138
|
Seagate ST336607FC (36.4GB - 10000 RPM FC-AL) |
Disks
|
390-0056
|
Seagate ST336704FC (36.4GB - 10000 RPM FC-AL) |
Disks
|
390-0168
|
Seagate ST373207FC (73.4GB - 10000 RPM FC-AL) |
Disks
|
390-0278
|
Seagate ST373207FC (73.4GB - 10000 RPM FC-AL), RoHS:Y |
Disks
|
390-0115
|
Seagate ST373307FC (73.4GB - 10000 RPM FC-AL) |
Disks
|
390-0073
|
Seagate ST373405FC (73.4GB - 10000 RPM FC-AL) |
Fibre Channel
|
375-3108
|
2Gb PCI Dual FC Host Adapter |
Fibre Channel
|
SG-XPCI2FC-QF2
|
2Gb PCI Dual FC Host Adapter |
Fibre Channel
|
X6768A
|
2Gb PCI Dual FC Host Adapter |
Fibre Channel
|
X6767A
|
2Gb PCI Single FC Host Adapter |
Fibre Channel
|
SG-XPCI1FC-QF2
|
2Gb PCI Single FC Host Adapter |
Fibre Channel
|
375-3102
|
2Gb PCI Single FC Host Adapter |
Fibre Channel
|
375-3383
|
2Gb PCI-X Single FC Host Adapter, RoHS:Y |
Fibre Channel
|
SG-XPCI1FC-QL2
|
2Gb PCI-X Single FC Host Adapter, RoHS:Y |
Fibre Channel
|
X6748A
|
Compact PCI (cPCI) Dual Channel FC |
Fibre Channel
|
X6730A
|
FC-AL SBus Card (FC100/S) |
Fibre Channel
|
540-2989
|
FC-AL SBus Card (FC100/S) |
Fibre Channel
|
501-5266
|
FC-AL SBus Host Adapter (FC100/S) |
Fibre Channel
|
370-2303
|
FC-AL SW-GBIC Module |
Fibre Channel
|
375-0085
|
Interconnect Board |
Fibre Channel
|
375-3157
|
JNI 2Gb PCI Dual FC Host Adapter |
Fibre Channel
|
SG-XPCI2FC-JF2
|
JNI 2Gb PCI Dual FC Host Adapter |
Fibre Channel
|
SG-XPCI1FC-JF2
|
JNI 2Gb PCI Single FC Host Adapter |
Fibre Channel
|
375-3156
|
JNI 2Gb PCI Single FC Host Adapter |
Fibre Channel
|
240-4839
|
Low Profile Bracket, RoHS:Y |
Fibre Channel
|
X6727A
|
PCI Dual FC Host Adapter+, RoHS:YL |
Fibre Channel
|
X6799A
|
PCI Single FC Host Adapter |
Fibre Channel
|
375-3019
|
PCI Single FC Host Adapter |
Fibre Channel
|
375-0040
|
Single Loop PCI FC-AL Host Adapter (FC100/P) |
Fibre Channel
|
X6729A
|
Single Loop PCI FC-AL Host Adapter (FC100/P) |
Parts
|
375-3030
|
SUN - DUAL FC NETWORK ADAPTER |
Parts
|
375-0118
|
SUN - SUN CPCI DUAL CHANNEL FC |
Power
|
300-1453
|
325 Watt Power Supply w NiCd Battery (pre-release) |
Power
|
370-3956
|
Battery Pack, NiMH |
Power
|
300-1454
|
Tectrol TC64S-1327 325 Watt Power Supply |
Rack
|
595-5932
|
4U single rackmount universal rail kit for mounting T3WG single brick models into Sun expansion cabinets (72-inch Sun StorEdge, Sun Fire, Sun Enterprise 5500/6500, or RETMA cabinets) |
Rack
|
X9677A
|
4U single rackmount universal rail kit for mounting T3WG single brick models into Sun expansion cabinets (72-inch Sun StorEdge, Sun Fire, Sun Enterprise 5500/6500, or RETMA cabinets) |
Rack
|
X9673A
|
72" Cabinet/E10000 4U Rack Mount Kit, |
Rack
|
595-5487
|
72" Cabinet/E10000 4U Rack Mount Kit, |
Rack
|
595-6047
|
7U Dual Rackmount Kit for 2-post or 4-post Telco Rack |
Rack
|
X9665A
|
7U Dual Rackmount Kit for 2-post or 4-post Telco Rack |
Rack
|
X9667A
|
7U dual rackmount universal rail kit for mounting T3ES and T3AES partner pair models into Sun expansion cabinets (72-inch Sun StorEdge, Sun Fire, Sun Enterprise 5500/6500, and RETMA cabinets) |
Rack
|
X9663A
|
7U dual rackmount universal rail kit for mounting T3ES and T3AES partner pair models into Sun expansion cabinets (72-inch Sun StorEdge, Sun Fire, Sun Enterprise 5500/6500, and RETMA cabinets) |
Rack
|
595-5933
|
7U dual rackmount universal rail kit for mounting T3ES and T3AES partner pair models into Sun expansion cabinets (72-inch Sun StorEdge, Sun Fire, Sun Enterprise 5500/6500, and RETMA cabinets) |
Rack
|
596-2990
|
ATO rack option for T3, includes 72" storage rack, fan tray, front door and T3 manual |
Rack
|
SG-ARY040A
|
ATO rack option for T3, includes 72" storage rack, fan tray, front door and T3 manual |
Rack
|
595-5540
|
E5500/6500 68" Cabinet 4U Rack Mount Kit |
Rack
|
X9674A
|
E5500/6500 68" Cabinet 4U Rack Mount Kit |
Rack
|
X9664A
|
E5500/6500 68" Cabinet 7U Rack Mount Kit |
Rack
|
595-5517
|
E5500/6500 68" Cabinet 7U Rack Mount Kit |
Rack
|
X9629A
|
E5500/6500 68" Cabinet Air Baffle |
Rack
|
340-6485
|
E5500/6500 68" Cabinet Air Baffle |
Rack
|
595-4551
|
FC Hub Rack Mount Kit |
Rack
|
X6735A
|
FC Hub Rack Mount Kit |
Rack
|
595-6718
|
Sun Rack 900 Rack Mount Kit for T3 Array (pair - 7RU) |
Rack
|
X6837A
|
Sun Rack 900 Rack Mount Kit for T3 Array (pair - 7RU) |
Rack
|
X6836A
|
Sun Rack 900 Rack Mount Kit for T3 Array (single - 4RU) |
Rack
|
595-6717
|
Sun Rack 900 Rack Mount Kit for T3 Array (single - 4RU) |
Rack
|
X9676A
|
T3 Mounting Tray Kit |
Switch/Hub
|
X6746A
|
|
Switch/Hub
|
SG-XSW64-BASE
|
64 Port Base Unit 2Gb FC Switch (32 ports included with base unit) |
Switch/Hub
|
370-5790
|
64 Port Base Unit 2Gb FC Switch (32 ports included with base unit) |
Switch/Hub
|
370-5847
|
8 Port 2Gb FC Blade (Add up to 4 to SG-XSW64-BASE to achieve 64 ports) |
Switch/Hub
|
SG-XSW64-BLADE-8P
|
8 Port 2Gb FC Blade (Add up to 4 to SG-XSW64-BASE to achieve 64 ports) |
Switch/Hub
|
370-4035
|
Ancor SANbox-8 Switch |
Switch/Hub
|
370-4863
|
Brocade 2250 16-port FCAL switch |
Switch/Hub
|
370-4395
|
Brocade 2400 8-port FCAL switch |
Switch/Hub
|
370-4396
|
Brocade 2800 16-Port FC switch |
Switch/Hub
|
370-5449
|
Brocade Silkworm 12000 16-Port FC Switch Module |
Switch/Hub
|
SG-XSWBRO12000-MOD
|
Brocade Silkworm 12000 16-Port FC Switch Module |
Switch/Hub
|
SG-XSWBRO12000-32P
|
Brocade Silkworm 12000 Switch with 32 Ports |
Switch/Hub
|
370-5748
|
Brocade Silkworm 12000 Switch with 32 Ports |
Switch/Hub
|
370-4749
|
Brocade Silkworm 12000 Switch with 64 Ports |
Switch/Hub
|
SG-XSWBRO12000-64P
|
Brocade Silkworm 12000 Switch with 64 Ports |
Switch/Hub
|
SG-XSWBRO3200
|
Brocade Silkworm 3200 8-Port FC Switch |
Switch/Hub
|
370-5769
|
Brocade Silkworm 3200 8-Port FC Switch |
Switch/Hub
|
370-4949
|
Brocade Silkworm 3800 16-Port FC Switch |
Switch/Hub
|
SG-XSWBRO3800
|
Brocade Silkworm 3800 16-Port FC Switch |
Switch/Hub
|
SG-XSWBRO3900
|
Brocade Silkworm 3900 32-Port FC Switch |
Switch/Hub
|
370-6078
|
Brocade Silkworm 3900 32-Port FC Switch |
Switch/Hub
|
370-3012
|
FC-100 Hub / Sun StorEdge F100 Hub |
Switch/Hub
|
X6732A
|
FC-100 Hub / Sun StorEdge F100 Hub |
Switch/Hub
|
340-5773
|
Slide Rail |
Switch/Hub
|
540-4372
|
StorEdge Network FC Switch-8 |
Switch/Hub
|
540-5404
|
Sun StorEdge Network 2GB FC Switch-16 |
Switch/Hub
|
SG-XSW16-2GB
|
Sun StorEdge Network 2GB FC Switch-16 |
Switch/Hub
|
SG-XSW8-2GB
|
Sun StorEdge Network 2GB FC Switch-8 |
Switch/Hub
|
540-5554
|
Sun StorEdge Network 2GB FC Switch-8 |
Switch/Hub
|
540-4751
|
Sun StorEdge Network FC Switch-16 |
Switch/Hub
|
SG-XSW16-32P
|
Sun StorEdge Network FC Switch-16 |
|
|
|