0
On Queue
Product Range
#

Sun Storedge A5200 Disk Array

(877) 667-8383    

Sun Storedge A5200 Disk Array The Sun StorEdge[tm] A5200 array provides a high-density, high-availability data storage solution for the enterprise. This fibre channel disk array offers excellent throughput, reliability, availability, and serviceability. Incorporating hot-plug, redundant components and dual fibre channel loops into a modular, networked, building-block architecture, this array is an ideal solution for mission-critical environments. Performance and capacity scale together, supporting departmental systems up to multi-terabyte data centers. With the Sun StorEdge A5200 array, you can deploy storage networks across your enterprise easily and cost-effectively. Sun Storage Automated Diagnostic Environment is an integral availability tool that provides health management services to help ensure high availability for Sun StorEdge arrays.

Highlights

  • Key Applications:
    An open, scalable, redundant storage solution for businesses who demand high availability and high performance. The Sun StorEdge A5200 array also offers a very high density of storage for businesses with limited floor space. Ideal for data warehousing, DSS, network file services and enterprise clusters

  • Key Specifications:
    36.4-GB or 73.4-GB models available. 100 MB/sec FC-AL from host to drives for performance and connectivity. VERITAS Volume Manager increases reliability by supporting RAID levels 0, 1, 0+1, 5. Increased spindle density: 22 drives per subsystem.

  • Key Benefits:
    Fully redundant RAID configurations support mission-critical applications. High RAS hot-plug power supplies, fans, interface boards, and disk drives. Flexible rackmountable, configurations for scalability. Higher performance: both throughput and response time. Improved RAS: diagnostics, configuration, installation.

  • Key Related Software:
    • Sun StorEdge[tm] Availability Suite software
    • Sun StorEdge Performance Suite software
    • Sun StorEdge Resource Management Suite software
    • Sun StorEdge Utilization Suite software

  • Key Industries:
    The Sun StorEdge A5200 array is well-suited for the capacity and performance requirements required by modern databases, operations application servers, network data services, and performance-oriented systems. Ideal for businesses requiring maximum storage per square foot of floor space, high performance with very high availability, and scalability to grow their storage easily.

  • Requirements:
    • Solaris[tm] 2.6 Operating Environment or higher
    • The enclosure is designed to be mounted in a standard Sun system or expansion cabinet, or stand alone on a tabletop

Sun Storedge A5200 Disk Array Specifications

Standard Interfaces
Drives Dual-ported 10K RPM FC-AL FS-SCA-2 (3.5-in.)
Dual-ported 15K* RPM RC-AL FS-SCA-2 (3.5-in.)
Note: *Availabile with 36 GB drive.
Capacity and Performance
36.4 GB drives 800 GB max array (22 drives)
4.8 TB max rack mounted (132 drives)
73.4 GB drives 1.6 TB max array (22 drives)
9.6 TB max rack mounted (132 drives)
Host Connectivity
Supported host bus adapters SBus dual channel host adapter FC-AL and with one GBIC module

Sun StorEdge PCI dual channel host adapter FC-AL with internal FC interface

Sun StorEdge PCI single channel and Sun StorEdge cPCI dual Fibre Channel host adapater FC-AL with optical interface
Fibre Channel Interface Standards
Standards ANSI Fibre Channel FC-PH X3230-1995
ANSI SCSI Fibre Channel Protocol X3.269-1996
Optical modules 100 MB/sec (1 GB/sec) full duplex
Shortwave laser GBIC; optical longwave laser GBIC
Fibre cable type 50 micrometer multimode, ST type connectors, 9 micrometer single mode
Maximum cable length 500 meters multimode, 10 km single mode
Software
Supported Software Sun StorEdge[tm] Traffic Manager software
Sun Cluster software 2.2 and 3.0
VERITAS Volume Manager
Solaris[tm] Operating Environments 2.6, 7, 8, 9
Windows NT Operating Environments 4.0SP, 3.0
Hardware Platforms
Supported Hardware Sun Enterprise[tm] 220R, 250, 420R, 450, 3500-6500 and 10000 servers
Sun Fire[tm] 280R, 3800, 4800, 4810, 6800, V480, V880, 12K, 15K servers
Ultra[tm] 60, 80 workstations
Sun Blade[tm] 1000 workstation
Netra[tm] t 1125, 1405 servers
Reliability, Availability, Serviceability
Redundancy FC-AL 7-port hubs
Dual FC-AL loops
Power supplies
Variable speed fans
Dual-port, FC-AL adapter (SBus)
Interface boards
High availability RAID 1+0
Dual FC-AL loops
Dual-port, FC-AL drives
Dual-port, FC-AL adapter (SBus)
Dynamic multipathing
Automatic loop failover
Online serviceable components DC power supplies
Variable speed fans
Interface boards
Dual-port disk drives
FC-AL loops
DC power supplies
FRU-level diagnostics
Configurations
Standalone 22 hot-plug dual-port FC-AL disk drives mounted front and rear
Three hot-plug, high reliability power supplies
Two variable-speed hot-plug fans with rotation and temperature sensors
Two hot-plug interface boards with up to two FC-AL 100 MB/sec GBIC modules each
Electro-luminescent display panel with status displays for disk drives, fans, fiber links, and power on self-test
Rack-mounted Up to six arrays (using 22-drive enclosures), up to four FC-AL hubs, 2-m to 15-m fiber-optic cables, 72-in. Sun StorEdge Expansion Rack mount with dual power sequencers
Environment
  Array Rackmounted
AC Power 100-240 VAC, 47-63 Hz, 5 A at 200 VAC, 10 A at 100 VAC 200-240 VAC, 47-63 Hz, 2 x 24 A
Input power 650 W 3900 W
Operating acoustic noise 6.6 bels (at 25º C/77º F)
Declared noice emissions in accordance with ISO 9296
8.0 bels (at 25º C/77º F)
Declared noice emissions in accordance with ISO 9296
Heat output 2220 BTUs/hr maximum 13,320 BTUs/hr maximum
Airflow clearance 15.24 cm (6.0 in.) all sides 51 cm (20 in.) left, 0 right,
61 cm (24 in.) front and rear
Regulations
  Array Rackmounted
Meets or exceeds the following requirements
Safety UL/CSA-60950, EN60950, IEC950 CB Scheme with all country deviations, IEC825-1, 2 and CFR21 Part 1040. UL/CSA-60950, EN60950, IEC950 CB Scheme with all country deviations, IEC825-1, 2 and CFR21 Part 1040.
Ergonomics EK1-ITB-2000  
Complies with the following when installed in a Sun StorEdge Expansion Rack mount:
RFI/EMI FCC EN55022/CISPR22 CLASS A
FCC CFR47, Part 15 CLASS A
EN61000-3-2, EN61000-3-3
EN55022/CISPR22 CLASS A
FCC CFR47, Part 15 CLASS A
EN61000-3-2, EN61000-3-3
Immunity EN55024 EN55024
Regulatory Markings CE, FCC-A, ICES-003-A, C-tick, VCCI-A, GOST-R, BSMI-A, MIC, UL/cUL, TUV-GS CE, FCC-A, ICES-003-A, C-tick, VCCI-A, GOST-R, BSMI-A, MIC, UL/cUL, TUV-GS
Dimensions and Weight
  Array Rackmounted
Height 22.7 cm (9.01 in.) = 5.2U 187 cm (73.5 in.)
Width 49.5 cm (19.65 in.) 61 cm (24 in.)
Depth 62.5 cm (24.81 in.) 93 cm (36.5 in.)
Weight 35 kg (79 lb.) approx.
(without disk drives)
394 kg (867 lb.) approx. maximux
(will six full arrays)
Weight 54 kg (120 lb.) approx.
(with disk drives)
n/a
Power cord 1.83 m (6 ft.) 4.6 m (15 ft.)


Sun StorEdge A5200 Bill of Materials
Cables
X3858A
Cables
X3859A
Cables
X9715A
Fibre Optical Cable SC/SC, 5M
Cables
180-1955
Han 6HsB to Blue 32A IEC309 (INTL), RoHS:Y
Cables
180-1954
Han 6HsB to NEMA L6-30P,4M (US), RoHS:Y
Cables
537-1006
Sun - 3rd Party SC to SC, 15m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum)
Cables
X978A
Sun - 3rd Party SC to SC, 15m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum)
Cables
X973A
Sun - 3rd Party SC to SC, 2m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum)
Cables
537-1004
Sun - 3rd Party SC to SC, 2m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum)
Cables
537-1020
Sun - 3rd Party SC to SC, 50m, Multimode, Duplex, 50/125um, Ceramic, Plenum ($100 minimum)
Drives
540-4191
18.2GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates
Drives
X6720A
18.2GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates
Drives
X6724A
36.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates
Drives
540-4525
36.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates
Drives
540-5178
36.4GB - 15000 RPM FC-AL, Disk Assembly with 1 bracket
Drives
X6763A
36.4GB - 15000 RPM FC-AL, Disk Assembly with 1 bracket
Drives
X6742A
73.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates
Drives
540-4905
73.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates
Drives
X6710A
9.1GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket
Drives
540-3869
9.1GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket
Drives
340-4288
Plate
Drives
340-5928
Plate
Drives
340-6640
Plate
Drives
340-7269
Plate, RoHS:Y
Drives
390-0011
Seagate ST318203FC
Drives
390-0034
Seagate ST318304FC
Drives
390-0070
Seagate ST336605FC
Drives
390-0137
Seagate ST336607FC
Drives
390-0035
Seagate ST336704FC
Drives
390-0099
Seagate ST336752FC (36.4GB - 15000 RPM FC-AL)
Drives
390-0130
Seagate ST336753FC (36.4GB - 15000 RPM FC-AL)
Drives
390-0165
Seagate ST373207FC (73.4GB - 10000 RPM FC-AL)
Drives
390-0121
Seagate ST373307FC (73.4GB - 10000 RPM FC-AL)
Drives
390-0071
Seagate ST373405FC
Drives
370-3647
Seagate ST39102FC
Drives
390-0016
Seagate ST39103FC
Interfaces
375-3108
2Gb PCI Dual FC Host Adapter
Interfaces
SG-XPCI2FC-QF2
2Gb PCI Dual FC Host Adapter
Interfaces
X6768A
2Gb PCI Dual FC Host Adapter
Interfaces
X6767A
2Gb PCI Single FC Host Adapter
Interfaces
SG-XPCI1FC-QF2
2Gb PCI Single FC Host Adapter
Interfaces
375-3102
2Gb PCI Single FC Host Adapter
Interfaces
375-3383
2Gb PCI-X Single FC Host Adapter, RoHS:Y
Interfaces
SG-XPCI1FC-QL2
2Gb PCI-X Single FC Host Adapter, RoHS:Y
Interfaces
X6748A
Compact PCI (cPCI) Dual Channel FC
Interfaces
X6730A
FC-AL SBus Card (FC100/S)
Interfaces
540-2989
FC-AL SBus Card (FC100/S)
Interfaces
501-5266
FC-AL SBus Host Adapter (FC100/S)
Interfaces
370-2303
FC-AL SW-GBIC Module
Interfaces
X6731A
FC-AL SW-GBIC Module
Interfaces
501-2948
Horizontal Interconnect Board
Interfaces
540-2864
Interconnect Assembly
Interfaces
501-2951
Interface Board
Interfaces
540-2988
Interface Board Assembly
Interfaces
X6734A
Interface Board Assembly
Interfaces
240-4839
Low Profile Bracket, RoHS:Y
Interfaces
X6727A
PCI Dual FC Host Adapter+, RoHS:YL
Interfaces
375-3019
PCI Single FC Host Adapter
Interfaces
X6799A
PCI Single FC Host Adapter
Interfaces
375-0040
Single Loop PCI FC-AL Host Adapter (FC100/P)
Interfaces
X6729A
Single Loop PCI FC-AL Host Adapter (FC100/P)
Interfaces
375-3030
SUN - DUAL FC NETWORK ADAPTER
Interfaces
375-0118
SUN - SUN CPCI DUAL CHANNEL FC
Interfaces
501-2947
Vertical Interconnect Board
Memory
375-0087
32MB SBus Fast Write Cache
Memory
X6738A
32MB SBus Fast Write Cache
Memory
X6745A
32MB SBus Fast Write Cache
Memory
375-0012
32MB SBus NVRAM Board
Memory
X1075A
32MB SBus NVRAM Board
PC Boards and Backplanes
501-4158
11-Slot FC Disk Backplane
Power Supplies
300-1295
Zytec EPO71265 310 Watt Power Supply
Power Supplies
X9687A
Zytec EPO71265 310 Watt Power Supply
Rack Mount Kits and Accessories
X9818A
72 inch StorEdge Expansion Cabinet Front Door Kit
Rack Mount Kits and Accessories
595-4999
72 inch StorEdge Expansion Cabinet Front Door Kit
Rack Mount Kits and Accessories
595-4954
72 inch Sun StorEdge Expansion Cabinet Cooling Kit
Rack Mount Kits and Accessories
X9819A
72 inch Sun StorEdge Expansion Cabinet Cooling Kit
Rack Mount Kits and Accessories
X6735A
FC Hub Rack Mount Kit
Rack Mount Kits and Accessories
595-4551
FC Hub Rack Mount Kit
Rack Mount Kits and Accessories
595-4940
Sun StorEdge A5x00 68 inch Cabinet Mount Kit
Rack Mount Kits and Accessories
X9654A
Sun StorEdge A5x00 68 inch Cabinet Mount Kit
Rack Mount Kits and Accessories
X9655A
Sun StorEdge A5x00 72 inch Cabinet Mount Kit
Rack Mount Kits and Accessories
595-4951
Sun StorEdge A5x00 72 inch Cabinet Mount Kit
Switches
X6746A
Switches
370-4863
Brocade 2250 16-port FCAL switch
Switches
370-4395
Brocade 2400 8-port FCAL switch
Switches
370-4396
Brocade 2800 16-Port FC switch
Switches
370-3012
FC-100 Hub / Sun StorEdge F100 Hub
Switches
X6732A
FC-100 Hub / Sun StorEdge F100 Hub
Switches
540-4372
StorEdge Network FC Switch-8
Switches
540-4751
Sun StorEdge Network FC Switch-16
Switches
SG-XSW16-32P
Sun StorEdge Network FC Switch-16
Transceivers
370-3722
FC-AL Long Wave GBIC
Transceivers
X6737A
FC-AL Long Wave GBIC
Transceivers
370-4379
FC-AL Short Wave GBIC