0
On Queue
Product Range
#

Sun Storedge 6900 Series

(877) 667-8383    

Sun Storedge 6900 Series The Sun StorEdge 6900 series is an ideal solution for midrange storage consolidation. Designed with simplicity in mind, the series is easy to order, deploy, and manage. These systems help lower total cost of ownership (TCO) by maximizing storage utilization, providing control of more storage with fewer resources, and protecting your existing storage investment. Simply add your Sun StorEdge arrays to the Sun StorEdge 6900 series systems. The integrated virtualization engine allows highly granular logical units (LUNs) to be allocated between multiple host platforms via a simple point-and-click interface. Sun StorEdge Traffic Manager software provides load-balanced, scalable I/O performance for transaction-intensive applications. Integrated call-home and remote diagnostic capabilities enable proactive service and support. In addition, Sun offers specific professional services to help your IT infrastructure adapt to shifting workload requirements and rapidly changing business needs. Sun Storage Automated Diagnostic Environment is an integral availability tool that provides health management services to help ensure high availability for Sun StorEdge integrated storage systems.

Highlights

  • Key Applications:
    Pretested, pre-integrated, fully supported storage system is optimized for the Solaris[tm] Operating Environment — maximizing application uptime. Customers can leverage existing storage investments in the award-winning Sun StorEdge array. Sun StorEdge 6900 series features multi-platform support for the latest SAN features and supports the latest versions of Microsoft Windows, Red Hat Linux, IBM AIX and HP/UX.

  • Key Specifications:
    Out-of-band storage service processor enhances system availability and reliability — provides proactive local and remote monitoring, configuration, diagnostics, and call-home capabilities. Professional implementation, installation, configuration, and assessment services are available. Compatible with Sun StorEdge Resource Management, Availability, Utilization, and Performance Suites software for full interoperability

  • Key Benefits:
    Highly cost-effective storage virtualization capability delivers excellent IOPs performance, enhanced system utilization, and simplified resource management. Consolidation enables quick and easy management of open-SAN storage pools. Full-fibre, positive-scaling architecture helps maximize performance and growth.

  • Requirements:
    • Solaris[tm] 8 Operating Environment
    • Microsoft Windows NT and Windows 2000

Sun Storedge 6900 Specifications

Standard Interfaces
36.4 GB drives Dual-ported 10K and 15K RPM FC-AL FS-SCA-2 (3.5-in.)
73.4 GB drives Dual-ported 10K RPM FC-AL FS-SCA-2 (3.5-in.)
181.6 GB drives Dual-ported 7200 RPM FC-AL FS-SCA-2 (3.5-in.)
Capacity and Performance
  6910 6960
Power receptacles required (US) Two NEMA per cabinet L6-30P for 200-240 VAC

(International) Two 32A, single phase IEC 309 connected to 220-240 VAC
(US) Two NEMA per cabinet L6-30P for 200-240 VAC

(International) Two 32A, single phase IEC 309 connected to 240-240 VAC
36 GB drives 1.9 TB max cabinet (54 drives) 1.9 TB max cabinet (54 drives)

5.2 TB max system (total of 144 drives with expansion cabinet)
73 GB drives 3.9 TB max cabinet (54 drives) 3.9 TB max cabinet (54 drives)

10.9 TB max system (total of 144 drives with expansion cabinet)
181.6 GB drives 9.8 TB max cabinet (54 drives) 9.8 TB max cabinet (54 drives)

26 TB max system (total of 144 drives with expansion cabinet)
Host Connectivity
Supported host bus adapters Sun StorEdge 1 Gb and 2 Gb PCI single Fibre Channel network adapters
Sun StorEdge 1 Gb and 2 Gb PCI dual Fibre Channel network adapters
Sun StorEdge SBUS dual Fibre Channel network adapter
Sun StorEdge cPCI dual Fibre Channel network adapter
Emulex LP8000-F1/N1* (Windows environment)
QLogic QLA2200F/66* (Linux environment)
Note: *All non-Sun host bus adapters supported by third-party vendor.
Integrated switches** Dual Fibre Channel switches
Note: **Also available without integrated switches.
Host connect F port (Fabric port)
Maximum Hosts Connections 6910 6960
7 (direct connect) 14 (direct connect)
Software
Operating System Solaris[tm] Operating Environments 8, 9
Microsoft Windows NT 4.0 (SP6 and SP6A)
Microsoft Windows 2000 Advanced Server (SP2)
Red Hat Linux ver. 7.2
Supported software Sun StorEdge Availability Suite software
Sun StorEdge Utilization software
Sun StorEdge Performance Suite software
Sun StorEdge Resource Management Suite software
Sun StorEdge Traffic Manager software
Solstice DiskSuite[tm] 4.2.1 software
VERITAS Volume Manager 3.2 software
VERITAS NetBackup 3.4 software
Solstice Backup[tm] 6.0 or greater software
Sun Cluster 3.0 update 2 software
VERITAS Cluster Server 2.0 software
Hardware Platforms
Supported hardware Sun Enterprise[tm] 220R, 250, 420R, 450, 3500-6500, and 10000 servers
Sun Fire[tm] 280R, V480, V880, 3800, 4800, 4810, 6800, 12K, and 15K servers
Maximum logical device support 6910 6960
1-256 LUNs 1-512 LUNs
Environment
AC power 200-240 VAC @ 47-63 Hz single phase
  6910 6960
Heat output maximum ~14,000 BTU ~14,000 BTU
Note: ~26,000 BTU for Sun StorEdge 6960 system with expansion cabinet
Temperature-operating 5º C to 35º C (41º F to 95º F)
Temperature-nonoperating -20º C to 60º C (-4º F to 140º F)
Shock-operating 4.0 g for maximum duration of 11 ms (half-sinewave)
Shock-nonoperating 10.0 g for maximum duration of 11 ms (half-sinewave)
Vibration-operating 5 to 500 Hz @ 0.25 g sinusoidal
Vibration-nonoperating 5 to 500 Hz @ 1.0 g sinusoidal
Humidity-operating 20% to 80%, RH, noncondensing, max gradient 10% per hour
Humidity-nonoperating 5% to 93%, RH, noncondensing, max gradient 10% per hour
Altitude-operating -1000 ft. to + 10,000 ft. (-305 m to 3048 m)
Altitude-nonoperating -1000 ft. to + 40,000 ft. (-305 m to 12,192 m)
Regulations>
Meets or exceeds the following requirements:
Safety UL/CSA-60950, EN60950, IEC950 CB Scheme with all country deviations, IEC825-1, 2, and CFR21 Part 1040
Ergonomics EK1-ITB-2000
RFI/EMI EN55022/CISPR22 Class A, FCC CFR47, Part 15 Class A, EN61000-3-2, EN61000-3-3
Immunity EN55024
Regulatory Markings CE, FCC-A, ICES-003-A, C-tick, VCCI-A, GOST-R, BSMI-A, MIC, UL/cUL, TUV-GS
Dimensions and Weights
  6910 6960
Height 1905 mm (75 in.) 1905 mm (75 in.)
Width 607.1 mm (23.9 in.) 1214.1 mm (47.8 in.)
Depth 939.8 mm (37 in.) 939.8 mm (37 in.)
Weight 549 kg (1210 lb.) 1314 kg (2895 lb.)


Sun StorEdge 6900 Bill of Materials
Cables
X3858A
Cables
X3859A
Cables
X9734A
Fibre Channel Optical Cable LC/LC, 15M
Cables
537-1043
Fibre Channel Optical Cable LC/LC, 15M
Cables
537-1041
Fibre Channel Optical Cable LC/LC, 2M, 2.0M
Cables
X9732A
Fibre Channel Optical Cable LC/LC, 2M, 2.0M
Cables
X9733A
Fibre Channel Optical Cable LC/LC, 5M
Cables
537-1042
Fibre Channel Optical Cable LC/LC, 5M
Cables
537-1035
Fibre Channel Optical Cable LC/SC, 2M
Cables
X9722A
Fibre Channel Optical Cable LC/SC, 2M
Cables
180-1955
Han 6HsB to Blue 32A IEC309 (INTL), RoHS:Y
Cables
180-1954
Han 6HsB to NEMA L6-30P,4M (US), RoHS:Y
Cables
530-3812
RJ45-RJ45 Cable, 2.4M, RoHS:Y
Cables
530-3100
RJ45F to DB9F Adapter, RoHS:Y
Cables
530-2152
Serial Cable, 5M
Cables
X3836A
Serial Cable, 5M
Cables
530-3809
Serial Cable, 5M, RoHS:Y
Cables
537-1006
Sun - 3rd Party SC to SC, 15m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum)
Cables
X978A
Sun - 3rd Party SC to SC, 15m, Multimode, Duplex, 50/125um, Ceramic, PVC ($100 minimum)
Drives
540-5204
181.5GB - 7200 RPM FC-AL, Disk Assembly with one bracket
Drives
X6764B
181.5GB - 7200 RPM FC-AL, Disk Assembly with one bracket
Drives
X6714A
36.4GB - 10000 RPM FC-AL, Disk Assembly with one bracket
Drives
540-4367
36.4GB - 10000 RPM FC-AL, Disk Assembly with one bracket
Drives
540-5179
36.4GB - 15000 RPM FC-AL, Disk Assembly with one bracket
Drives
X6765B
36.4GB - 15000 RPM FC-AL, Disk Assembly with one bracket
Drives
540-4519
73.4GB - 10000 RPM FC-AL, Disk Assembly with one bracket
Drives
X6713A
73.4GB - 10000 RPM FC-AL, Disk Assembly with one bracket
Drives
540-4303
Bracket
Drives
390-0095
Fujitsu MAN3367FC (36.4GB - 10000 RPM FC-AL)
Drives
390-0096
Fujitsu MAN3735FC (73.4GB - 10000 RPM FC-AL)
Drives
390-0116
Fujitsu MAP3735FC (73.4GB - 10000 RPM FC-AL)
Drives
390-0150
Fujitsu MAS3367FC (36.4GB - 15000 RPM FC-AL)
Drives
390-0169
Fujitsu MAT3073FC (73.4GB - 10000 RPM FC-AL)
Drives
390-0191
Fujitsu MAU3036FC (36.4GB - 15000 RPM FC-AL)
Drives
390-0117
Hitachi DK32EJ-72FC (73.4GB - 10000 RPM FC-AL)
Drives
390-0170
Hitachi HUS1073FA (73.4GB - 10000 RPM FC-AL)
Drives
390-0057
IBM DDYF-T36950 (36.4GB - 10000 RPM FC-AL)
Drives
390-0102
Seagate ST1181677FCV (181.5GB - 7200 RPM FC-AL)
Drives
390-0023
Seagate ST136403FC (36.4GB - 10000 RPM FC-AL)
Drives
390-0036
Seagate ST173404FC (73.4GB - 10000 RPM FC-AL)
Drives
390-0072
Seagate ST336605FC (36.4GB - 10000 RPM FC-AL)
Drives
390-0138
Seagate ST336607FC (36.4GB - 10000 RPM FC-AL)
Drives
390-0056
Seagate ST336704FC (36.4GB - 10000 RPM FC-AL)
Drives
390-0101
Seagate ST336752FC (36.4GB - 15000 RPM FC-AL)
Drives
390-0127
Seagate ST336753FC (36.4GB - 15000 RPM FC-AL)
Drives
390-0168
Seagate ST373207FC (73.4GB - 10000 RPM FC-AL)
Drives
390-0278
Seagate ST373207FC (73.4GB - 10000 RPM FC-AL), RoHS:Y
Drives
390-0115
Seagate ST373307FC (73.4GB - 10000 RPM FC-AL)
Drives
390-0073
Seagate ST373405FC (73.4GB - 10000 RPM FC-AL)
Interfaces
375-3108
2Gb PCI Dual FC Host Adapter
Interfaces
SG-XPCI2FC-QF2
2Gb PCI Dual FC Host Adapter
Interfaces
X6768A
2Gb PCI Dual FC Host Adapter
Interfaces
X6767A
2Gb PCI Single FC Host Adapter
Interfaces
SG-XPCI1FC-QF2
2Gb PCI Single FC Host Adapter
Interfaces
375-3102
2Gb PCI Single FC Host Adapter
Interfaces
X6748A
Compact PCI (cPCI) Dual Channel FC
Interfaces
370-2303
FC-AL SW-GBIC Module
Interfaces
375-3157
JNI 2Gb PCI Dual FC Host Adapter
Interfaces
SG-XPCI2FC-JF2
JNI 2Gb PCI Dual FC Host Adapter
Interfaces
SG-XPCI1FC-JF2
JNI 2Gb PCI Single FC Host Adapter
Interfaces
375-3156
JNI 2Gb PCI Single FC Host Adapter
Interfaces
240-4839
Low Profile Bracket, RoHS:Y
Interfaces
X6727A
PCI Dual FC Host Adapter+, RoHS:YL
Interfaces
X6799A
PCI Single FC Host Adapter
Interfaces
375-3019
PCI Single FC Host Adapter
Interfaces
375-3048
SBus Dual FC Network Adapter
Interfaces
X6757A
SBus Dual FC Network Adapter
Interfaces
375-3030
SUN - DUAL FC NETWORK ADAPTER
Interfaces
375-0118
SUN - SUN CPCI DUAL CHANNEL FC
Other
370-4898
SSRR Modem
Power Supplies
300-1393
230V AC Power Sequencer
Processors
540-5199
Netra X1 Service Processor (pre-loaded with software)
Rack Mount Kits and Accessories
X9818A
72 inch StorEdge Expansion Cabinet Front Door Kit
Rack Mount Kits and Accessories
595-4999
72 inch StorEdge Expansion Cabinet Front Door Kit
Rack Mount Kits and Accessories
595-4706
72 inch Sun StorEdge Expansion Cabinet
Rack Mount Kits and Accessories
SG-XARY030A
72 inch Sun StorEdge Expansion Cabinet
Rack Mount Kits and Accessories
X9663A
7U dual rackmount universal rail kit for mounting T3ES and T3AES partner pair models into Sun expansion cabinets (72-inch Sun StorEdge, Sun Fire, Sun Enterprise 5500/6500, and RETMA cabinets)
Rack Mount Kits and Accessories
595-5933
7U dual rackmount universal rail kit for mounting T3ES and T3AES partner pair models into Sun expansion cabinets (72-inch Sun StorEdge, Sun Fire, Sun Enterprise 5500/6500, and RETMA cabinets)
Rack Mount Kits and Accessories
X9676A
T3 Mounting Tray Kit
Rack Mount Kits and Accessories
X1311A
Terminal Concentrator Mounting Bracket
Rack Mount Kits and Accessories
595-3617
Terminal Concentrator Mounting Bracket
Server
600-7882
Sun Fire V100 FRU 500MHz CPU, 512MB RAM, 1× 40GB Disk, 24X CD-ROM
Server
600-7996
Sun Fire V100 FRU 550MHz CPU, 512MB RAM, 1× 40GB Disk, 24X CD-ROM
Switches
SG-XSWBRO24K-MOD
Switches
X6746A
Switches
370-5574
10/100 Ethernet Hub
Switches
370-6820
16-Port Switch Module
Switches
SG-XSWBRO24K-32P
16-Port Switch Module
Switches
370-4170
24-Port Gigabit Ethernet Switch (WS-C3524-XL)
Switches
370-5790
64 Port Base Unit 2Gb FC Switch (32 ports included with base unit)
Switches
SG-XSW64-BASE
64 Port Base Unit 2Gb FC Switch (32 ports included with base unit)
Switches
SG-XSW64-BLADE-8P
8 Port 2Gb FC Blade (Add up to 4 to SG-XSW64-BASE to achieve 64 ports)
Switches
370-5847
8 Port 2Gb FC Blade (Add up to 4 to SG-XSW64-BASE to achieve 64 ports)
Switches
370-4035
Ancor SANbox-8 Switch
Switches
370-7046
Brocade 24000 Director 32-Port Switch
Switches
370-7047
Brocade 3250 8-Port FC Switch
Switches
370-6824
Brocade 3252 Value Line 8-Port FC Switch
Switches
SG-XSWBRO3250
Brocade 3252 Value Line 8-Port FC Switch
Switches
SG-XSWBRO3250VL2
Brocade 3252 Value Line 8-Port FC Switch
Switches
370-7048
Brocade 3850 16-Port FC Switch
Switches
370-6826
Brocade 3852 Value Line 16-Port FC Switch
Switches
SG-XSWBRO3850
Brocade 3852 Value Line 16-Port FC Switch
Switches
SG-XSWBRO3850VL2
Brocade 3852 Value Line 16-Port FC Switch
Switches
SG-XSWBRO3900
Brocade Silkworm 3900 32-Port FC Switch
Switches
370-6078
Brocade Silkworm 3900 32-Port FC Switch
Switches
370-4897
Hub - SuperStack
Switches
370-5732
McData 6064 Director Switch w/32 ports
Switches
SG-XSWMD6064-32P
McData 6064 Director Switch w/32 ports
Switches
SG-XSWM6140-64P
McData Intrepid 6140 140-port Switch with 64 Ports active
Switches
370-6131
McData Intrepid 6140 140-port Switch with 64 Ports active
Switches
370-6133
McData Intrepid 6140 140-port Switch with 64 ports active in a McData Fabricenter Rack (International power)
Switches
SG-XSWM6140-RK64I
McData Intrepid 6140 140-port Switch with 64 ports active in a McData Fabricenter Rack (International power)
Switches
SG-XSWM6140-RK64P
McData Intrepid 6140 140-port Switch with 64 ports active in a McData Fabricenter Rack (US power).
Switches
370-6132
McData Intrepid 6140 140-port Switch with 64 ports active in a McData Fabricenter Rack (US power).
Switches
370-6169
McData Sphereon 4300 12-port Switch
Switches
SG-XSWMD4300-12P
McData Sphereon 4300 12-port Switch
Switches
SG-XSWMD4500-8P
McData Sphereon 4500 24-port Switch with 8 ports activated
Switches
370-6085
McData Sphereon 4500 24-port Switch with 8 ports activated
Switches
SG-XSWMD4500-UPG
McData Sphereon 4500 8 port activation license key, activates 8 additional ports
Switches
370-4934
Network Terminal Concentrator, comes with preconfigured software
Switches
370-4684
Storage Virtualization Engine (SVE)
Switches
540-4372
StorEdge Network FC Switch-8
Switches
540-5404
Sun StorEdge Network 2GB FC Switch-16
Switches
SG-XSW16-2GB
Sun StorEdge Network 2GB FC Switch-16
Switches
540-5554
Sun StorEdge Network 2GB FC Switch-8
Switches
SG-XSW8-2GB
Sun StorEdge Network 2GB FC Switch-8
Switches
540-4751
Sun StorEdge Network FC Switch-16
Switches
SG-XSW16-32P
Sun StorEdge Network FC Switch-16
Switches
370-4276
Sun StorEdge Network FC-AL Switch 16 port